WindMaster and WindMaster Pro 1561-PS-0001. Issue 11 February 2017
________________________________________________________________________________________________________________________
19
6.6.2 WindMaster 1590-PK-050 Pipe Mount Box Connection Details and WindMaster and
WindMaster Pro Pipe Mount Box Connection Details (Spared Item 1590-PK-048).
See also the next page.
Part
WindMaster 1590
-
PK
-
050
Pipe Mount Integral Part
Pipe Mount Adaptor 1590
-
PK
-
048
Spared Item
Connector
Terminal
Connection
Name
Connection
Name
J1
PRT Excite +
(No Connection)
PRT Excite +
(wired connection)
PRT Excite
(No Connection)
PRT Excite
(
wired connection
)
PRT Sense +
(No Connection)
PRT Sense +
(
wired c
onnection)
PRT Sense
(No Connection)
PRT Sense
(
wired c
onnection)
Screen Ground
from WindMaster
Screen Ground
from WindMaster
Com
(communication)
Mode
(External Link to determine RS232 or
RS422/RS485)
Com
(communication)
Mode
(External Link to determine RS232 or
RS422/RS485)
Power 0V
Powe
r 0V
Power +V
Power +V
J2
Anemometer Transmit TXA (
-
)
Anemometer Transmit TXA (
-
)
Anemometer Transmit TXB (+)
Anemometer Transmit TXB (+)
Anemometer Receive RXA (
-
)
Anemometer Receive RXA (
-
)
Anemometer Receive RXB (
-
)
Anemometer Receive RXB
(
-
)
Analogue Out 4
(No Connection)
Analogue Out 4
(
wired c
onnection)
Analogue Out 3
(No Connection)
Analogue Out 3
(
wired c
onnection)
Analogue Out 2
(No Connection
Analogue Out 2
(
wired c
onnection
Analogue Out 1
(No Connection)
Analogue Out 1
(
wired c
onnection)
J3
Analogue In 1
Analogue In 1
Analogue Ground
Analogue Ground
Analogue In 2
Analogue In 2
Analogue Ground
Analogue Ground
Analogue In 3
Analogue In 3
Analogue Ground
Analogue Ground
Analogue In 4
Analogue In 4
An
alogue Ground
Analogue Ground
J4
(Jumper)
Com
-
CM
Communication mode
set by external
connection (Default Setting)
Communication mode
set by external
connection (Default Setting)
Com
-
OV
Set communication mode to
RS422/RS485 (Internal Link, external
link unnecessary)
Set communication mode to
RS422/RS485 (Internal Link, external
link unnecessary)
Com
-
V+
Set communication mode to RS232
(Internal Link, external link
unnecessary)
Set communication mode to RS232
(Internal Link, external link
unnecessary)
S
creen
Ground Pillar
Screen
The cable screen from the
WindMaster 31 way connector is
wired to a Ground Pillar
The cable screen from the
WindMaster 31 way connector is
wired to a Ground Pillar
Screen
Ground Pillar
Screen
The cable screen/s from user
equipment is wired to this Pillar using
M4 screw/washer/terminal fixings
supplied in the installation kit
The cable screen/s from user
equipment is wired to this Pillar using
M4 screw/washer/terminal fixings
supplied in the installation kit