IP address ►
Indicate the network address affected to the device. An IP address is made of four
numbers separated by a dot. Each number range from 0 to 255;
DHCP identier ►
Identier to be used when the LEDI Network IN is congured in DHCP mode. This
identier has 8 letters maximum. The default value is CRnnnnnn (where nnnnnn is
the serial number on 6 digits);
Network submask ►
Indicate the width of the network you use. For example, a network submask
255.255.255.0 indicates that only the last number change (in the example above,
address in the network can change between 192.168.10.1 to 192.168.10.254)
7
.
Gateway address ►
If you want the LEDI Network IN to communicate with devices outside the local
network, you must indicate a gateway that will be used to go outside local network;
Without gateway ►
Check this box when you don’t have a gateway on your network (or don’t want to
use it);
PRODUCT INFORMATION
Here is a description of the product information area:
Hardware ► GT serial number
Display the Gorgy Timing serial number of the product. This is a 6 digits number
which is the same than the one stamped on the bottom or background of the rack
Hardware ► Product code
Display the Gorgy Timing base code of the product without option (9257 for a LEDI
Network IN)
Ethernet Interface ► (MAC) Address
Indicate the Medium Access address of the Ethernet interface of the LEDI Network IN
Ethernet Interface ► Adapter Serial number
Indicate the serial number of the Ethernet interface of the LEDI Network IN. This
information can be useful for maintenance;
Firmware ► Description
Short text that describes which software is running on your product
7/ If you congure several devices to communicate on the same network, you must have the same network submask.
4. WEB INTERFACE