5. TOP / ALARM OUTPUT (‘A’, ‘R’ TYPE AND ‘G’ TYPE)
5.1. Pin-out
The 4 points plug on the ASCII and ALARM cards can provide a congurable time TOP
or synchro/power alarm TOP.
The 4 points plug has the following pin-out:
Static Relay Outputs 1 and 2 : ►
Pin 1, Pin 2 ► : without polarity
Max. switching voltage ► : 350 V AC/DC
Max. switching current ► : 130 mA
Open Collector output ►
Pin 4 ► : Gnd Pin 3 : +
Max. voltage ► : 45 V
Max. curren ► t : 30 mA