Installation
Grounding Grounding
Grounding
Theequipmentmustbegroundedtoreducethe
riskofstaticsparkingandelectricshock.Electric
orstaticsparkingcancausefumestoigniteor
explode.Impropergroundingcancauseelectric
shock.Groundallequipment,personnel,objects
beingsprayed,andconductiveobjectsinorclose
tothesprayarea.Theresistancemustnotexceed
1megohm.Groundingprovidesanescapewire
fortheelectriccurrent.
Whenoperatingtheelectrostaticgun,any
ungroundedobjects(suchaspeople,containers,and
tools)inthespraylocationcanbecomeelectrically
charged.
Thefollowingareminimumgroundingrequirements
forabasicelectrostaticsystem.Yoursystemmay
includeotherequipmentorobjectswhichmustbe
grounded.Yoursystemmustbeconnectedtoa
trueearthground.Checkgroundconnectionsdaily.
Checkyourlocalelectricalcodesandregulationsfor
detailedgroundinginstructions.
•
Allpersonsenteringthesprayarea:
mustwear
shoeshavingconductivesolessuchasleather,
orwearpersonalgroundingstraps.Donot
wearshoeswithnon-conductivesolessuchas
rubberorplastic.Ifglovesarenecessary,wear
theconductiveglovessuppliedwiththegun.If
non-Gracoglovesareworn,cutoffngersorpalm
areaofglovestoensureyourhandcontactsthe
groundedgunhandle.Conductiveglovesand
footwearmustnotexceed100megohmperEN
ISO20344,EN1149–5.
•
Objectbeingsprayed:
Keeptheworkpiecehangers
cleanandgroundedatalltimes.
•
ElectrostaticAir-AssistedSprayGun:
Ground
thegunbyconnectingtheGracoGrounded
AirHosetothegun,andconnectingtheair
hosegroundwiretoatrueearthground.See
CheckGunElectricalGrounding,page24.
•
Pump/uidsource:
Groundthepump/uidsource
byconnectingitsgroundwiretoatrueearth
ground.
•
Allelectricallyconductiveobjectsordevicesinthe
sprayarea:
mustbeproperlygrounded.
•
Fluidandwastecontainers:
Groundalluidand
wastecontainersinthesprayarea.Donotusepail
linersunlesstheyareconductiveandgrounded.
Whenushingthespraygun,thecontainerused
tocatchtheexcessuidmustbeelectrically
conductiveandgrounded.
•
Aircompressors:
Groundtheequipmentaccording
tothemanufacturer'srecommendations.
•
Allairanduidlines
mustbeproperlygrounded.
Useonlygroundedhoseswithamaximumof100
feet(30.5m)combinedhoselengthtoensure
groundingcontinuity
•
Theoorofthesprayarea:
mustbeelectrically
conductiveandgrounded.Donotcovertheoor
withcardboardoranynon-conductivematerial
whichwouldinterruptgroundingcontinuity
3A2495K
17