GunOverview
Smart Smart
Smart
Guns Guns
Guns
TheSmartGunmoduledisplayssprayingvoltage,
current,alternatorspeed,andthevoltagesetting(low
orhigh).Italsoallowstheusertochangetoalower
sprayingvoltage.Themodulehastwomodes:
•OperatingMode
•DiagnosticMode
Operating Operating
Operating
Mode Mode
Mode
Bar Bar
Bar
Graph Graph
Graph
SeeFig.2andSmartGunKey,page11.The
OperatingModedisplaysgundataduringnormal
spraying.Thedisplayusesabargraphtoshowthe
voltagelevelinkiloVolts(kV)andthecurrentlevelin
microAmperes(uA).Thebargraphrangeisfrom0
to100%foreachvalue.
IftheuAbargraphLEDsareblue,thegunisready
tospray.IftheLEDsareyelloworred,thecurrentis
toohigh.Theuidmaybetooconductive,orsee
ElectricalTroubleshooting,page37forotherpossible
causes.
Hz Hz
Hz
Indicator Indicator
Indicator
TheHzindicatorfunctionsthesameastheES
indicatoronstandardguns.Theindicatorlightsto
showthealternatorspeedstatus,andhasthree
colors:
•Greenindicatesthealternatorspeediscorrect.
•Iftheindicatorchangestoamberafteronesecond,
increasetheairpressure.
•Iftheindicatorchangestoredafteronesecond,
theairpressureistoohigh.Decreaseairpressure
untiltheindicatorisgreen.Tomaintainahigher
airpressure,installESOn/OffValveRestrictorKit
26A294.Then,adjustthepressureasneededto
ensuretoensuretheindicatorremainsgreen.
Voltage Voltage
Voltage
Adjustment Adjustment
Adjustment
Switch Switch
Switch
Thevoltageadjustmentswitch(VA)allowsthe
operatortochangefromlowtohighvoltage.
•Thehighvoltagesettingisdeterminedbythe
maximumvoltageofthegunandisnotadjustable.
•Thelowvoltageindicator(LO)lights
whentheswitchissettoLO.Thelow
voltagesettingisuseradjustable.See
AdjustingtheLowVoltageSetting,page10.
NOTE: NOTE:
NOTE:
IftheErrordisplayappears,theSmartmodule
haslostcommunicationwiththepowersupply.See
ErrorDisplay,page10,forfurtherinformation.
Figure2SmartGunModuleinOperatingMode
3A2495K9