Operation
Startup Startup
Startup
FollowallstepsunderGunSetupProcedure,page21.
Checkthefollowinglistdaily,beforestartingto
operatethesystem,tohelpensureyouofsafe,
ef󰘰cientoperation.
Alloperatorsareproperlytrainedtosafelyoperate
anautomaticelectrostaticairspraysystemas
instructedinthismanual.
Alloperatorsaretrainedinthe
PressureReliefProcedure,page26.
Thewarningsignprovidedwiththegunismounted
inthesprayareawhereitcanbeeasilyseenand
readbyalloperators.
Thesystemisthoroughlygroundedandthe
operatorandallpersonsenteringthesprayarea
areproperlygrounded.SeeGrounding,page17.
Theconditionofthegun’selectrical
componentshasbeencheckedasinstructedin
ElectricalTests,page32.
Ventilationfansareoperatingproperly.
Workpiecehangersarecleanandgrounded.
Alldebris(including󰘱ammable󰘱uidsandrags)is
removedfromthesprayarea.
All󰘱ammable󰘱uidsinthespraybootharein
approved,groundedcontainers.
Allconductiveobjectsinthesprayareaare
electricallygroundedandthe󰘱oorofthespray
areaiselectricallyconductiveandgrounded.
Shutdown Shutdown
Shutdown
Toreducetheriskofaninjury,followthe
PressureReliefProcedure,page26wheneveryou
areinstructedtorelievethepressure.
1.Flushthegun.SeeFlushing,page28.
2.FollowthePressureReliefProcedure,page26.
3.Hangthegunfromitshook,withthenozzle