Operation
Startup Startup
Startup
FollowallstepsunderGunSetupProcedure,page21.
Checkthefollowinglistdaily,beforestartingto
operatethesystem,tohelpensureyouofsafe,
efcientoperation.
•Alloperatorsareproperlytrainedtosafelyoperate
anautomaticelectrostaticairspraysystemas
instructedinthismanual.
•Alloperatorsaretrainedinthe
PressureReliefProcedure,page26.
•Thewarningsignprovidedwiththegunismounted
inthesprayareawhereitcanbeeasilyseenand
readbyalloperators.
•Thesystemisthoroughlygroundedandthe
operatorandallpersonsenteringthesprayarea
areproperlygrounded.SeeGrounding,page17.
•Theconditionofthegun’selectrical
componentshasbeencheckedasinstructedin
ElectricalTests,page32.
•Ventilationfansareoperatingproperly.
•Workpiecehangersarecleanandgrounded.
•Alldebris(includingammableuidsandrags)is
removedfromthesprayarea.
•Allammableuidsinthespraybootharein
approved,groundedcontainers.
•Allconductiveobjectsinthesprayareaare
electricallygroundedandtheoorofthespray
areaiselectricallyconductiveandgrounded.
Shutdown Shutdown
Shutdown
Toreducetheriskofaninjury,followthe
PressureReliefProcedure,page26wheneveryou
areinstructedtorelievethepressure.
1.Flushthegun.SeeFlushing,page28.
2.FollowthePressureReliefProcedure,page26.
3.Hangthegunfromitshook,withthenozzle
pointingdown.
3A2495K
27