Maintenance
Maintenance Maintenance
Maintenance
Daily Daily
Daily
Care Care
Care
and and
and
Cleaning Cleaning
Cleaning
Checklist Checklist
Checklist
Checkthefollowinglistdailyuponcompletionof
equipmentusage.
Flushthegun.SeeFlushing,page28.
Cleanthe󰘱uidandairline󰘰lters.
Cleantheoutsideofthegun.See
CleantheGunDaily,page30.
Cleantheaircapandspraytipdaily,at
aminimum.Someapplicationsrequire
morefrequentcleaning.Replacethespray
tipandaircapiftheyaredamaged.See
CleantheGunDaily,page30.
Checktheelectrodeandreplace
ifbrokenordamaged.See
ElectrodeReplacement,page41.
Checkfor󰘱uidleakagefromthegunand󰘱uid
hoses.Tighten󰘰ttingsorreplaceequipment
asneeded.
Checkelectricalgrounding.See
CheckGunElectricalGrounding,page24.
Flushing Flushing
Flushing
Flushbeforechanging󰘱uids,before󰘱uidcandry
intheequipment,attheendoftheday,before
storing,andbeforerepairingequipment.
Flushatthelowestpressurepossible.Check
connectorsforleaksandtightenasnecessary.
Flushwitha󰘱uidthatiscompatiblewiththe󰘱uid
beingdispensedandtheequipmentwettedparts.
Toreducetheriskof󰘰re,explosion,orelectric
shock:
TurnOFF(O)theESOn-Offswitchbefore
󰘱ushingthegun.
Alwaysgroundequipmentandwastecontainers.
Flushequipmentonlyinawell-ventilatedarea.
UseonlyGroupIIA󰘱ushingmaterials.
Non-ignitable󰘱uidsarepreferred.
Toavoidstaticsparkingandinjuryfrom
splashing,always󰘱ushatthelowestpossible
pressure.
NOTICE NOTICE
NOTICE
Donotusemethylenechlorideasa󰘱ushingor
cleaningsolventwiththisgunasitwilldamage
nyloncomponents.
1.TurnOFF(O)theESOn-Offswitch.
2.FollowthePressureReliefProcedure,page26.
3.Removeandcleantheaircapandspraytip.
283A2495K