CE5000-UM-251-9370 9-1
9 TROUBLESHOOTING
9 TROUBLESHOOTING
9.1 The Plotter is Turned On But Doesn’t Operate
Symptom Verication item Solution
The control panel’s LED
lamp does not light or
the LCD does not display
anything.
(1) Is the plotter being supplied with
power?
No .....Check that the power cord is
securely connected to the plotter’s
AC line inlet.
Yes .... Verify item (2).
(2) IstheFPC504302exiblecable
securely connected to the main
board and the control panel?
No .....Connecttheexiblecable
securely.
Yes .... Verify item (3).
(3) IstheFPC504302exiblecable
broken?
No .....Verify item (4).
Yes .... ReplacetheFPC504302exible
cable.
(4) Is the AC line electrical output
correct?
No .....Change the AC line.
Yes .... Verify item (5).
(5) Does the power supply unit have
a 5 V output?
No .....Replace the power supply unit.
Yes .... Replace the main board.