CE5000-UM-251-9370 7-4
7 ELECTRICAL ADJUSTMENTS
7.4 Clearing the Non-Volatile RAM
When you replace the main board, you must clear the Non-Volatile RAM (NOV-RAM).
If you clear the Non-Volatile RAM, you will lose the setup parameters for each adjustment.
Input the adjustment values to the main board after you clear the Non-Volatile RAM.
How to clear the Non-Volatile RAM.
(1) Set SW1 to the NOV-RAM clear mode as shown below.
For old type of main board:
Set bit 3 to ON.
SW1
1234
ON
OFF
For new type of main board:
Dip Switch 1 2 3 4 Model
SW1
1234
ON
OFF
OFF OFF OFF ON CE5000-40CRP (Craft ROBO Pro)
SW1
1234
ON
OFF
ON OFF OFF ON CE5000-60
SW1
1234
ON
OFF
OFF ON OFF ON CE5000-120
SW1
1234
ON
OFF
ON ON OFF ON CE5000-120AP
(2) Turn on the power to the plotter.
(3) The NOVRAM INIT. menu appears. The plotter immediately starts to clear the parameters on the NOV-
RAM, and then sets the default values.
NOVRAM INIT.
(4) When the NOV-RAM clear operation is complete, a menu for model selection appears on the LCD panel.
(This menu is not displayed when the main board is new type.)
CE5000-40CRP
(5) Select your plotter model using the UP and DOWN ARROW keys, and then press the ENTER key to
register your plotter model setting.
(This is not necessary when the main board is new type.)
(6) When the model selection is complete, the END message appears on the LCD panel.
CE5000-40CRP END
(7) Turn off the power to the plotter.
(8) Return the SW1 setting to normal mode as shown in the subsection 7.1.