EasyManua.ls Logo

GRAPHTEC CE5000 SERIES - How to Replace the Y-Flexible Cable

GRAPHTEC CE5000 SERIES
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CE5000-UM-251-9370 6-28
6 DISASSEMBLY AND REASSEMBLY
6.2.13 How to Replace the Y-exible Cable
How to detach the Y-Flexible cable
(1) Detach the right side cover (see Subsection 6.1.1).
(2) Detach the center cover (see Subsection 6.1.3 or 6.1.4).
(3) Detach the front guide (see Subsection 6.1.5 or 6.1.6).
(4) Removethewiringharnesstie-wrapholdingtheY-exiblecableandthecoreontheY-relayboard.
(5) Detachthecoreattachedwithdouble-sidedadhesivetapetotheY-relayboard.
(6) DisconnecttheY-exiblecablefromconnectorJ501ontheY-relayboard.
(7) DisconnecttheY-exiblecablefromconnectorJ1onthemainboard.
(8) Removethefourplasticrivetsholdingtheexiblecablestopper.
Flexible cable
stopper
Y flexible cable
Plastic rivet
(9) RemovetheY-exiblecableattachedwithdouble-sidedadhesivetapetotheY-rail.