Model G0452/P/Z (Mfg. Since 08/12)
-47-
The depth scale on the infeed table can be cali-
brated or "zeroed" if it is not correct.
To calibrate the depth scale:
1. Set the outfeed table height as described
in the Setting Outfeed Table Height sub-
section.
2. Place a straightedge across the infeed and
outfeed tables.
3. Adjust the infeed table until it is level with the
outfeed table, as illustrated in Figure 70.
Figure 71. Depth-of-cut pointer adjusted to “0”
position.
Figure 70. Infeed table adjusted even with
outfeed table and knife at TDC.
Straightedge
Outfeed
4. Using a screwdriver, adjust the scale pointer
exactly to “0” (Figure 71).
Depth-of-cut
pointer
Calibrating Depth
Scale