Chapter 3 G Command
117
I Programming
M29
RATP(F76.3)
G84 executed
Output S command
RGTA(G61.0)
FIN(G4.3)
The spindle rotation operation
Operation 1
Shielding 2
Operation 3
The spindle CCW signal SFR
z Specify M29 and G74/G84 at the same block
G84 shows a sample for the following time-sequence
M29
RATP(F76.3)
G84 executed
Output S command
RGTA(G61.0)
FIN(G4.3)
The spindle rotation operation
Operation 1
Shielding 2
Operation 3
The spindle CCW signal SFR
z The explanation of time sequence
The spindle rotation operation means that the rotation axis is shifted to the position control mode
(namely, the servo spindle is needed to send a switch signal in position mode), and check the position mode
arrival signal of servo spindle.
3.30.6 The Cancellation of Rigid Tapping Mode
z The rigid tapping mode is canceled by G80
z Specify other canned cycles by G codes
z The other G codes of group 1.
z CNC resetting
The signal descending of F76.3 along the signal with canceling the rigid tapping of PLC, if the state
RTCRG of parameter No.588 is equal to 1, the system is then performed the next block without waiting for
the rigid tapping mode signal which G61.0 is set to 0;
When the state parameter No.588 (CRG) =0, the time sequence is as follows:
When the state parameter No.588 (CRG) =1, the time sequence is as follows: