EasyManua.ls Logo

GSK 980MDc - The 2 Nd, 3 Rd and 4 Th Reference Point Return G30

GSK 980MDc
473 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GSK980MDc Milling CNC System User Manual
48
I Programming
G29 Y Only Y axis performs the command returning from the reference point
G29 Z Only Z axis performs the command returning from the reference point
G29 X Z Only X and Z axes perform the command returning from the reference point
G29 X Y Only X and Y axes perform the command returning from the reference point
G29 Y Z Only Y and Z axes perform the command returning from the reference point
G29 X Y Z
X, Y and Z perform the command returning from the reference point
Process for command action:
(1) The command axis direction performs positioning at the intermediate point specified by G28 (from
point R
to B), the action is
①
→
.
②
(2) The positioning is performed from intermediate point to specified point (from point B to C), moving
to the intermediate and command point at a rapid feedrate, the action is ③→④.
Note 1:G29 is specified after G28, if an intermediate point is not specified by any of axes, the system alarm will be
generated.
Note 2: It is incremental distance against the intermediate point in G91 coordinate programming.
3.13 The 2nd, 3rd and 4th Reference Point Return G30
Reference point is a fixed point on the machine. By parameters (No.1240~No.1243) it can set four
reference points in the machine coordinate system.