=0
:
Real-time detection for the stability of voltage is performed.
0 7 0 1 *** *** *** *** *** *** *** EXTIO
EXTIO =1: External remote IO is valid;
=0: External remote IO is invalid.
0 8 0 0 *** *** *** *** *** L2 L1 L0
L2, L1, L0
:
Interface language selection:
Language L2 L1 L0
Chinese 0 0 0
English 0 0 1
France 0 1 0
Spanish 0 1 1
Germen 1 0 0
Italian 1 0 1
Russian 1 1 0
Korean 1 1 1
0 8 0 1 DISP *** *** *** *** *** PROD ***
PROD =1
:
Rel.coord. don't with comp
=0
:
Rel.coord. with comp
DISP =1
:
Enter absolute page after power on;
=0
:
Enter relative page after power on.
0 8 1 0 *** *** *** MER MCL MKP *** M30R
MER =1
:
After the last block is executed in MDI operation, the executed programs are not deleted;
=0
:
After the last block is executed in MDI operation, the executed programs are deleted.
MCL =1
:
The programs edited in MDI operation are deleted by the reset operation;
=0
:
The programs edited in MDI operation are not deleted by the reset operation.
MKP =1
:
In MDI operation, when M02 or M30 is executed, the edited MDI programs are not deleted;
=0
:
In MDI operation, when M02 or M30 is executed, the edited MDI programs are deleted.
M30R =1
:
Cursor return after executing M30 in Auto mode;
=0
:
Cursor don't return after executing M30 in Auto mode.
0 8 3 0 *** *** *** *** KEY *** *** ***
KEY1 =1
:
Prog. switch ON after power on;
=0
:
Prog. switch OFF after power on.
0 8 3 1 *** *** *** *** *** *** *** MGEH
MGEH =1: Aided programming function is shielded;
=0
:
Aided programming function is unshielded.
1 0 1 0 Amount of axes
Setting range
:
3
~
5