Handling Precautions
Service Manual for Accutherm Ultra Printer A-vii
When servicing the terminal in the field the FST first must ground himself to the
terminal chassis which is powered off and connected to earth ground, as shown in
the picture below.
GTECH Manufacturing Specification
GTECH assemblies comply with IEC 61000-4-2 recommendations for severity
typically in excess of level three. IEC stands for International Electrotechnical
Commission. The specification is for Electromagnetic Compatibility for Industrial
Process Measurement and Control Equipment.
Part two specifies electrostatic discharge requirements and states that our
equipment must withstand 15KV air discharges and 8KV contact discharges. Both
positive and negative polarity discharges must comply.