Parameter Settings:
IP Address: IP address range: 1.0.0.0 to
223.255.255.255 (excluding 127.nnn.nnn.nnn).
Subnet Mask: Subnet Mask Range: 1.0.0.0 to
255.255.255.255.
Gateway: Gateway range: 1.0.0.0 to
223.255.255.255 (excluding 127.nnn.nnn.nnn).
VISA Resource name
TCPIP0::169.254.129.17::1026::SOCKET
DHCP
A. Press the System button to enter the system
interface followed by pressing the F1 (Interface)
button to configure port parameter.
B. Press the F4 (LAN) button to configure
internet port parameter.
C. Press the F2 (Config) button to configure
relevant parameter.
D. Press the F1 (DHCP) button. The unit will be
assigned an IP address, subnet mask, the
default gateway and other network parameters
from the DHCP server. The corresponding
parameters will be shown in the parameter
area. Use the arrow keys to view the settings.