EasyManuals Logo

GW Instek GPP-1326 User Manual

GW Instek GPP-1326
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
GPP Series User Manual
136
Function
Sets the method of automatically generated time
and the corresponding parameter of delay.
Description
<value0> The duration of “ON” state.
<value1> The duration of “OFF” state.
FIX (fixed time) sets <value0> and <value1> time,
which ragne from 1s to 300s. The default setting of
delay time is enabled when only a time parameter
is specified.
Constant duration will be generated by the pattern
of either monotonous increase or monotonous
decrease when INC (monotonous increase) or DEC
(monotonous decrease) is set. Starting from the
base time, it gradually increases or decreases by
steps and further generates duration. Base time
(<value0>) and step value (<value1>) are available
for setting, the mechanical relation of both of which
is base time + output group number * step value
300s. The available range of setting value for
<value0> is from 1s to (300s-output group number
* step value). The available range of setting value
for <value1> is from 1s- int{( 300s-base
time/output group number). The default duration
is base time when only a time parameter is
specified.
Example
:DELAy2:TIME:GENE INC,3,5
Sets the CH2 method of automatically generated
time for delay as monotonous increase, base time as
3s, step value as 5s.
Command
:DELAy[1|2]:TIME:GENErate?
Function
Queries the method of automatically generated
time for delay and the corresponding parameter.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPP-1326 and is the answer not in the manual?

GW Instek GPP-1326 Specifications

General IconGeneral
BrandGW Instek
ModelGPP-1326
CategoryPower Supply
LanguageEnglish

Related product manuals