Command
:RECOrder[1|2|3|4]:ENABle {ON|OFF}
Function
Sets the channel recorder ON or OFF.
Example
:RECOrder2:ENABle ON
Enables CH2 recorder.
Command
:RECOrder[1|2|3|4]:ENABle?
Function
Queries the state of channel recorder.
Example
:RECOrder2:ENABle?
Returns the state of CH2 recorder, ON or OFF.
Command
:SEQUence[1|2]:CYCLEs {N|I}[,<value>]
Function
Sets the cycle number of sequence.
Description
{N|I} Sets cycle number as infinite (I) or specified
value (N, <value>).
Example
:SEQUence2:CYCLEs N,20
Sets the cycle number of sequence as 20.
Command
:SEQUence[1|2]:CYCLEs?
Function
Queries the cycle number of the sequence.
Example
:SEQUence2:CYCLEs?
Queries the cycle number of the sequence.
Returns to I or N, <value>.
Command
:SEQUence[1|2]:ENDState {OFF|LAST}
Function
Sets terminate state of sequence.
Description
{OFF|LAST} Output disabled (OFF): instrument
automatically disable output when output is
complete. The last group (LAST): instrument stays
at the output state of the last group when output is
complete.