41
Figure 65 Completing the device driver installation wizard
Setting terminal parameters
To configure and manage the switch through the console port, you must run a terminal emulator
program, TeraTermPro or PuTTY, on your configuration terminal. You can use the emulator program
to connect a network device, a Telnet site, or an SSH site. For more information about the terminal
emulator programs, see the user guides for these programs
The following are the required terminal settings:
Bits per second—9600.
Data bits—8.
Stop bits—1.
Parity—None.
Flow control—None.
Powering on the switch
1. Before powering on the switch, verify that the following conditions are met:
{ All the fan tray slots have a fan tray installed.
{ The power cords are connected correctly.
{ The input power voltage is as required by the switch.
{ The console cable is connected correctly.
{ The configuration terminal (a PC, for example) has started, and its serial port settings are
consistent with the console port settings on the switch.