298
PARAMETERS
June 1999
96-8000
DISPLAY ACTUAL When set to 1, displays the actual spindle speed on the Current
Commands display page.
TSC PRG ENBL Enables purge output on TSC option.
RESERVED Reserved for later use.
SPND DRV LCK This bit must be set to 1 if machine is equipped with a non-Haas
vector spindle drive. This bit must be set to 1 if the machine has
a 50 taper spindle or a non-Haas vector drive.
RESERVED Reserved for later use
CNCR SPINDLE (Concurrent Spindle) When set to 1, the spindle will be commanded to
start concurrently with other commands in the same block. In the
following example, with this bit set to 1, the spindle will start at the
same time as the rapid move:
G0 X-1. S7500 M3;
RESERVED Reserved for later use.
HAAS VECT DR (Haas Vector Drive) This bit must be set to 1 if machine is equipped
with a HAAS vector spindle drive. When set to 1, voltage to the Haas
vector drive is displayed in the diagnostics display as DC BUSS.
UP ENCL TEMP (Microprocessor Enclosure Temperature) When set to 1, the
enclosure temperature will be displayed on INPUTS2 screen of the
diagnostics display.
HAAS RJH (Haas Remote Jog Handle) This bit must be set to 1 if the machine is
equipped with a Haas 5-Axis Remote Jog Handle.
SPIN TEMP NC (Spindle Temperature Sensor Normally Closed) This bit specifies the
type (normally open or normally closed) of the spindle temperature
sensor. This bit should be set to 1 for machines with a Haas vector
drive, and 0 for machines that do not have a vector drive.
AIR DRV SHTL This bit will cause the machine to use discrete outputs 21 and 26 to
command the shuttle to move in and out. On mills with the Air Driven
Shuttle it must be set to 1. On all other mills it must be set to 0.
GIMBAL SPNDL Used on VR-Series mills. This bit will cause the machine to check
that the Z,A and B axes are at zero before a tool change is started. If
one is not, alarm 150 will be generated. On mills with the gimbaled
Spindle it must be set to 1. On all other mills it must be set to 0.
NO MFIN CKPU When this bit is set, it will prevent checking of MFIN at power-up. It
should be set for 1 for all machines that have the new Haas Automatic
Pallet Changer attached, and 0 for all other machines.
D:Y SW ENABLE (Delta Wye switch enabled). This bit is used for the Vector Drive. The
bit enables the switching of spindle motor windings, provided the
hardware ENABLE is installed, and the proper parameters are set. If
this switch is set, but bit 19 is not, then the winding switching will
only be done when the spindle is at rest, depending on the target
speed of the spindle.