EasyManuals Logo

Haas VF-1 User Manual

Haas VF-1
564 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #300 background imageLoading...
Page #300 background image
300
PARAMETERS
June 1999
96-8000
HS3 SDMTCRSL This parameter bit is for the HS-3 sidemount tool changer. It must be
set to 1 on all HS-3 mills, and 0 on all other mills.
SAFETY INVERT This bit supports the CE door interlock that locks when power is
turned off. For machines that have the regular door lock that locks
when power is applied, this bit must be set to 0. For machines that
have the inverted door lock, this bit must be set to 1.
INV SPD DCEL Inverese Spindle Speed Deceleration. When this parameter is set to 1,
the spindle decelerates faster at lower speeds, resulting in a shorter
deceleration time.
SWAP A & C This parameter causes the A and C axes to be swapped internally.
This parameter bit should be set to 1 for the bridge mill. All other mills
should set this bit to 0.
INV SPD DCEL Inverse Spindle Speed Deceleration When this parameter is set to 1,
the spindle decelerates faster at lower speeds, resulting in shorter
deceleration time.
Parameter 279 X LSC GAIN MULTIPLIER
This parameter is used on machines with linear scales. Linear scales are used to
continuously correct any errors in the encoder position. The parameter determines the gain of
the correction factor, that is, how fast it corrects. This parameter should be set to 40.
Parameter 280 Y MAX 3rd DERIV
See parameter 279 for description
Parameter 281 Z MAX 3rd DERIV
See parameter 279 for description
Parameter 282 A MAX 3rd DERIV
See parameter 279 for description
Parameter 283 B MAX 3rd DERIV
See parameter 279 for description
Parameter 284 RESERVED
Parameter 285 X LSC OFFSET
This parameter is used on machines with linear scales. This parameters account for the
unused portion of the lead screw between zero and the actual motor. This parameters should
be a positive value (400000) unless the NEG COMP DIR bit for the axis is set, in which case
this parameter should be a negative value (-400000.)
Parameter 286 Y LSC OFFSET
See parameter 285 for description.
Parameter 287 Z LSC OFFSET
See parameter 285 for description.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haas VF-1 and is the answer not in the manual?

Haas VF-1 Specifications

General IconGeneral
BrandHaas
ModelVF-1
CategoryPower Tool
LanguageEnglish

Related product manuals