Page #324 background imageLoading...
Page #324 background image
324
ALARMS
June 1999
96-8000
408 RS-232 Number Range Error Check your program. The program will be stored but the bad
data is turned into a comment.
409 RS-232 Invalid N Code Bad Parameter or Setting data. User was loading settings or
parameters and something was wrong with the data.
410 RS-232 Invalid V Code Bad parameter or setting data. User was loading settings or
parameters and something was wrong with the data.
411 RS-232 Empty Program Check your program. Between % and % there was no program
found.
412 RS-232 Unexpected End of Input Check Your Program. An ASCII EOF code was found in the input
data before program receive was complete. This is a decimal
code 26.
413 RS-232 Load Insufficient Memory Program received doesnîš’t fit. Check the space available in the
LIST PROG mode and possibly delete some programs.
414 RS-232 Buffer Overflow Data sent too fast to CNC. This alarm is not normally possible
as this control can keep up with even 115200 bits per second.
Computer sending data may not respond to X-OFF
415 RS-232 Overrun Data sent too fast to CNC. This alarm is not normally possible
as this control can keep up with even 115200 bits per second.
416 RS-232 Parity Error Data received by CNC has bad parity. Check parity settings,
number of data bits and speed. Also check your wiring.
417 RS-232 Framing Error Data received was garbled and proper framing bits were not
found. One or more characters of the data will be lost. Check
parity settings, number of data bits and speed.
418 RS-232 Break Break condition while receiving. The sending device set the line
to a break condition. This might also be caused by a simple
break in the cable.
419 Invalid Function For DNC A code found on input of a DNC program could not be
interpreted.
420 Program Number Mismatch The O code in the program being loaded did not match the O
code entered at the keyboard. Warning only.
429 Flpy Dir Insufficient Memory Floppy memory was almost full when an attempt was made to
read the floppy directory.
430 Floppy Unexpected End of Input Check your program. An ASCII EOF code was found in the input
data before program receive was complete. This is a decimal
code 26.
431 Floppy No Prog Name Need name in programs when receiving ALL; otherwise has no
way to store them.