HARDI CONTROLLER 5500
Technical specifications
Supply voltage ..............................................................................12 Volt DC
Controlled shutdown “low battery”.................................................. 9 Volt DC
Maximum supply ..........................................................................16 Volt DC
Maximum peak .............................................................................28 Volt DC
Ambient temperature ............................................................ – 5°C to + 70°C
Memory ................................................................. Flash PROM non-volatile
Digital transducers (option 2, 3 and 4) ..................................... Square signal
Frequency ............................................................................ 0.5 Hz to 2 kHz
Trigger high ..................................................................... 4.0 to 12.0 Volt DC
Trigger low......................................................................... 0.0 to 2.0 Volt DC
Analog transducers (option 1)
Supply ................................................................................................... 12 V
Input ............................................................................................ 4 to 20 mA
Minimum speed for volume regulation ............................................. 0.5 km/h
Flow ranges for the flow transducersFlow ranges for the flow transducers
Flow ranges for the flow transducersFlow ranges for the flow transducers
Flow ranges for the flow transducers
Identification code Orifice Flow
No outside groove 20.0 mm 10 to 300 l/min
One outside groove 13.5 mm 5 to 150 l/min
Two outside grooves
36.0 mm 35 to 600 l/min
Pressure drop over 13.5 mm orifice is 1 bar at 150 l/min.
Packaging informationPackaging information
Packaging informationPackaging information
Packaging information
Materials used for packaging are environmentally compatible.
They can be safely deposited or they can be burnt in an incinerator.
RecyclingRecycling
RecyclingRecycling
Recycling
Cardboard: Can recycle up to 99% and therefore should be put into
the waste collection system.
Polyethylene: Can be recycled.
When the Controller and Spray Box has completed its working life, it must
be thoroughly cleaned. The synthetic fittings can be incinerated.
The printed circuit boards and metallic parts can be scrapped.