Suction Valve (Blue symbols)
This valve is to select suction from main tank, rinsing tank or external tank.
The handle is turned so the desired symbol is just below the steel knob.
Agitation Valve and Flushing Valve (Green symbols)
With the adjustable agitation valve it is possible to combine spraying with a high volume rate at high pressure with agitation
at the same time. Flushing of the external filling equipment.
This is regulated by the valve: The valve is marked with an arrow on the disc which indicates the amount of liquid that passes
through the valve.
Choose your own valve setting, depending on the tank contents:
• The handle is turned to a position near the tip of the arrow: Only a small amount of liquid is allowed to pass the valve
resulting in a lesser extent of agitation.This is recommended when using chemicals with a low density to prevent
foaming in the tank.
If flushing the filling equipment, this setting would be a light flushing.
• The handle is turned to a position in the wide end of the arrow: A large amount of liquid will pass the valve resulting
in a large extent of agitation. This is recommended when using chemicals with a high density, which will tend to settle
at the bottom of the tank.
If flushing the filling equipment, this setting would be a thorough flushing.
External Filling Valve (Red symbol)
The valve is used when filling from an external tank or reservoir.
Turning the valve starts/stops the filling process.
Main tank Spraying
Internal tank cleaning
(Rinsing nozzles)
Pressure draining or
TurboFiller
Main tank Rinsing tank
Filling from external tank
Adjustable agitation
Flushing of external filling
line