VPL400-X: Install Manual
21JULY2023 | 630-00159 B
32
TROUBLESHOOTING
VPL400-X: SECTION 7
SECTION 7
TROUBLESHOOTING
A BRAKE RELEASE toggle switch is only used during emergency lowering of the platform or positioning the
platform during installation when power is not applied to the unit. See Figure 7-1.
If the brake release switch is enabled, the plaorm
may dri. This should only be used in emergency
lowering situaons or during installaon. Toggle
switch should be ipped "down" during normal
operaon.
WARNING
!
15A BREAKER
The unit has a 15A breaker equipped for the motor
circuit. If tripped, it can be reset to restore normal
function.
2A BREAKER
The unit has a 2A breaker equipped for the interlock
circuit. If tripped, it can be reset to restore normal
function.
Figure 7-2
Figure 7-1