44 HMX6803+ and OP+HMX+ Installation and Operation Manual
Copyright © 2009, Harris Corporation
Chapter 3: Operation
Discovering Your Module Using CCS Software
To discover your module, your Navigator software must be in Build mode.
1. If the Discovery window is not open, click Tools > Discovery in the main
menu.
A Discovery window opens, most likely in the bottom left corner of the
screen.
2. Click Options, and then click Add.
3. Enter the IP address of the frame that contains your module, the frame that
contains your ICE6800+ module, or the frame that contains a 6800+ETH
module that provides access to your module.
4. Click OK to close the Add Host dialog box, and then OK again to close the
Discovery Options dialog box.
5. Click Start.
This triggers Navigator to run a discovery.
Discovery Completed is displayed in the Discovery pane.
6. Click Save to save the results of your discovery to the Discovery folder of
the Navigation pane.
7. Switch to Control mode by selecting Operational Mode > Control from
the main menu.
8. Double-click HMX6803+ in the Navigation pane.
The Control window opens displaying the module’s controls.
You can now switch to Control mode by selecting Operational Mode >
Control from the main menu. Double-click HMX6803+ in the Navigation pane
(OP+HMX+ modules are also referred to as HMX6803+ in the Navigator
pane). The Control dialog box opens displaying the module’s controls.
Setting HMX6803+ Remote Control Parameters
Table 3-10 lists all of the remote control parameters and options for the
HMX6803+. To access these parameters, you can use CCS Navigator, an HTTP
web browser, or a third-party SNMP-based control application (depending on
your host frame’s options). See your software user manual for more
information.
Note that rows in the table that contain a range of numbers in parentheses
indicate that a series of numbered parameters contain that same function and
range.
Legend
Bold option=Indicates that this is the default setting for the parameter.
Rows of the table that are in grey are read-only parameters.