DAC-42(A)-x-PN
Page 67
DAC-42(A)-x-PN
Manual
Revision: 1.0
22.01.2024
ID
Hex
ID
dec
W/R
Nam
Function Unit
Min
Max
Def
Description
0x69
105 R/W
E10
Solenoid current adaptation A --- 50
110
100
Variable adjustment of max. current
Initial current solenoid A
3.000 V = 30 % of max. rated current
Initial current solenoid B
0x6C
108 R/W
E13
Dither Amplitude A V 0
3000
0
0x6D
109 R/W
E14
Dither Frequency A Hz 1
300
0
---
0x6E
110 R/W
E15 Selection set point S1.06 (U/I)
--- 0
11
1
off = Deactivated
1 = Voltage -10V..+10V
2 = Voltage 0..10V
3 = Voltage 5V+-5V
4 = Voltage 5V+-4.5V w/o signal observation
5 = Voltage 5V+-4.5V with signal observation
6 = 0..20mA w/o cable fract. det.
7 = 10+-10mA w/o cable fract. det.
8 = 4..20mA w/o cable fract. det.
9 = 4..20mA with cable fract. det.
10 = 12+-8mA w/o cable fract. det.
8mA with cable fract. det.
0x70
112 R/W
E17 Set value activation mode --- 0
3
off
off = 4 digital, 3 analog active
1 = 5 digital SP, 3 analog active
2 = only 4 digital active
3 = only 5 digital active
0x71
113 R/W
E18
Error / Comparator output selection
--- off
1
off
off = break off
1 = break on
Modus 3,4,10,11 --- off
5
off
off = break off, comp. positive logic
1 = break on, comp. positive logic
2 = break follows comp. positive logic
3 = break not and comp. positive logic
4 = break and comp. negative logic
5 = break not and comp neg. logic
Modus 6,8 --- off
13
off
off = break off, comp. positive logic
1 = break on (supply) comp. pos. log
2 = break follows comp., comp. pos. log
3 = break log. not comp., comp. pos. log
4 = break log. not comp., comp. neg. log
5 = break a. comp. same, comp. neg. l.
6 = break follow Comp1, comp. pos. log
7 = break log. not Comp1, comp. pos. l.
8 = break log. not Comp1, comp. neg. l.
9 = break a. Comp1 same, comp. neg. l.
10 = break follow Comp2; comp. pos. l.
11 = break log. not Comp2, comp. pos. l.
12 = break log. not Comp2; comp. neg. l.
13 = break a. Comp2 same, comp. neg. l
0x72
114 R/W
E19 Factor for analog output
(depends on HW + SW version)
V/V -400
400
100
100 == Factor 1.00
0xA3
163 R/W
E 22
Profinet Slave Address --- 0
32
0
0 = No bus function
1 = Standard Profinet
2..5 = Multiple Slave Profinet
-1000 == -1.000 V; 1000 == 1.000 V