Organization mode of operation | Parameters
9
HEIDENHAIN | MANUALplus 620 | User's Manual | 12/2017
611
Settings for the simulation
General settings (114800)
Restart with M99 (114801)
On: Simulation restarts at the beginning of the program
Off: Simulation stops
Path-delay (114802)
[s]: Waiting time after each path display. This setting influences the speed of simula-
tion
Software limit switch active (114803)
On: Software limit switch is also active during simulation
Off: Software limit switch is not active during simulation
Simulation
Processing times for NC functions (general) (115000)
Time allowance for tool change (115001)
[s]: These times are used as non-machining times for the time calculation function
Time allowance for gear shifting (115002)
[s]: These times are used as non-machining times for the time calculation function
General time allowance for M functions (115003)
[s]: These times are used as non-machining times for the time calculation function
Simulation
Processing times for M functions (115100): Individual time allowances for a maximum of 20 M functions
T01 (115100)
Number of the M function
Time allowance for the M function
[s]: Time calculation adds this time to the general time allowance for M
functions
TXX (115100)
See T01
Simulation
Definition of the (default) window size (115200): The simulation adapts the window size to the
workpiece blank. If no workpiece blank has been programmed, the simulation will use the default
window size
Datum position in X (115201)
[mm]: Distance of the coordinate origin from the lower edge of the window
Datum position in Z (115202)
[mm]: Distance of the coordinate origin from the left edge of the window
Delta X (115203)
[mm]: Vertical extension of the graphic window