Tables and overviews | Compatibility in DIN programs
10
HEIDENHAIN | MANUALplus 620 | User's Manual | 12/2017
697
M functions:
M30 with NS.. is converted to M0 M99 NS
M97 is removed for single-channel controls
All other M functions are left unchanged
G functions:
Currently, the control does not support the following G
functions: G98, G204, G710, G906, G907, G915, G918, G975
The following G functions are not supported by single-channel
controls: G62, G63, G162
A warning will be issued if the following G functions are used in
a contour description: G10, G38, G39, G52, G95, G149. These
functions are now modal
Warnings may occur for the thread functions G31, G32, G33; it
is recommended to test these functions
The Contour mirroring/shifting G121 function is converted to
G99 but the principle of function is compatible
A warning will be issued for G48 because the principle of
function has changed.
A warning will be issued for G916, G917 and G930 because the
principle of function has changed. Functions must be supported
by the PLC
Names of external subprograms:
When an external subprogram is called, the converter prefixes
CONV_... to the name
Multichannel programs on single-channel controls:
On single-channel controls, programs for two slides are
converted to a single slide and the Z-axis movements of the
second slide are converted to G1 W… or G701 W…
In the program head, #SLIDE $1$2 is replaced by #SLIDE $1
$ statements preceding the block number are removed
$2 G1 Z… is converted to G1 W… and G701 Z… to G701 W…
The word SLIDE ALLOCATION is removed (but remembered
internally for converting the subsequent blocks)
Synchronization statements $1$2 M97 are removed
Datum shifts for slide 2 are saved as comments; paths of