EasyManua.ls Logo

HEIDENHAIN TNC 320 - Cycle Parameters

HEIDENHAIN TNC 320
465 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BASIC ROTATION over two studs (Cycle 402, DIN/ISO: G402) 13.4
13
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
313
Cycle parameters
Q268 1st stud: center in 1st axis? (absolute):
Center of the first stud in the reference axis of
the working plane. Input range -99999.9999 to
99999.9999
Q269 1st stud: center in 2nd axis? (absolute):
Center of the first stud in the secondary axis of
the working plane. Input range -99999.9999 to
99999.9999
Q313 Diameter of stud 1?: Approximate diameter
of the first stud. Enter a value that is more likely
to be too large than too small. Input range 0 to
99999.9999
Q261 Meas. height stud 1 in TS axis? (absolute):
coordinate of the ball tip center (= touch point in the
touch probe axis) at which stud 1 is to be measured.
Input range -99999.9999 to 99999.9999
Q270 2nd stud: center in 1st axis? (absolute):
Center of the second stud in the reference axis
of the working plane. Input range -99999.9999 to
99999.9999
Q271 2nd stud: center in 2nd axis? (absolute):
Center of the second stud in the secondary axis
of the working plane. Input range -99999.9999 to
99999.9999
Q313 Diameter of stud 2?: Approximate diameter
of the second stud. Enter a value that is more likely
to be too large than too small. Input range 0 to
99999.9999
Q315 Meas. height stud 2 in TS axis? (absolute):
coordinate of the ball tip center (= touch point in the
touch probe axis) at which stud 2 is to be measured.
Input range -99999.9999 to 99999.9999
Q320 Set-up clearance? (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP in the touch probe table.
Input range 0 to 99999.9999
Q260 Clearance height? (absolute): coordinate in
the touch probe axis at which no collision between
tool and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999
Q301 Move to clearance height (0/1)?: Definition
of how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
NC blocks
5 TCH PROBE 402 ROT OF 2 STUDS
Q268=-37 ;1ST CENTER 1ST AXIS
Q269=+12 ;1ST CENTER 2ND AXIS
Q313=60 ;DIAMETER OF STUD 1
Q261=-5 ;MEAS. HEIGHT STUD 1
Q270=+75 ;2ND CENTER 1ST AXIS
Q271=+20 ;2ND CENTER 2ND AXIS
Q314=60 ;DIAMETER OF STUD 2
Q315=-5 ;MEAS. HEIGHT STUD 2
Q320=0 ;SET-UP CLEARANCE
Q260=+20 ;CLEARANCE HEIGHT
Q301=0 ;MOVE TO CLEARANCE
Q307=0 ;PRESET ROTATION
ANG.
Q305=0 ;NUMBER IN TABLE
Q402=0 ;COMPENSATION
Q337=0 ;SET TO ZERO

Table of Contents