EasyManua.ls Logo

HEIDENHAIN TNC 320 - Cycle Parameters

HEIDENHAIN TNC 320
465 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Touch Probe Cycles: Automatic Datum Setting
14.6 DATUM FROM INSIDE OF CIRCLE (Cycle 412, DIN/ISO: G412)
14
344
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
Cycle parameters
Q321 Center in 1st axis? (absolute): Center of the
pocket in the reference axis of the working plane.
Input range -99999.9999 to 99999.9999
Q322 Center in 2nd axis? (absolute): Center of the
pocket in the secondary axis of the working plane.
If you program Q322 = 0, the TNC aligns the hole
center to the positive Y axis. If you program Q322
not equal to 0, then the TNC aligns the hole center
to the nominal position. Input range -99999.9999 to
99999.9999
Q262 Nominal diameter?: Approximate diameter
of the circular pocket (or hole). Enter a value that
is more likely to be too small than too large. Input
range 0 to 99999.9999
Q325 Starting angle? (absolute): Angle between
the reference axis of the working plane and the first
touch point. Input range -360.000 to 360.000
Q247 Intermediate stepping angle? Q247
(incremental): Angle between two measuring
points. The algebraic sign of the stepping angle
determines the direction of rotation (negative =
clockwise) in which the touch probe moves to the
next measuring point. If you wish to probe a circular
arc instead of a complete circle, then program the
stepping angle to be less than 90°. Input range
-120.000 to 120.000
Q261 Measuring height in probe axis? (absolute):
Coordinate of the ball tip center (= touch point) in
the touch probe axis in which the measurement is
to be made. Input range -99999.9999 to 99999.9999
Q320 Set-up clearance? (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP in the touch probe table.
Input range 0 to 99999.9999
Q260 Clearance height? (absolute): coordinate in
the touch probe axis at which no collision between
tool and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999
Q301 Move to clearance height (0/1)?: Definition
of how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Q305 Number in table?: Enter the number in the
datum/preset table in which the TNC is to save
the coordinates of the pocket center. If Q303=1:
If you enter Q305=0, the TNC automatically sets
the display so that the new datum is on the pocket
center. If Q303=0: If you enter Q305=0, the TNC
writes to line 0 of the datum table. Input range 0 to
99999
NC blocks
5 TCH PROBE 412 DATUM INSIDE
CIRCLE
Q321=+50 ;CENTER IN 1ST AXIS
Q322=+50 ;CENTER IN 2ND AXIS
Q262=75 ;NOMINAL DIAMETER
Q325=+0 ;STARTING ANGLE
Q247=+60 ;STEPPING ANGLE
Q261=-5 ;MEASURING HEIGHT
Q320=0 ;SET-UP CLEARANCE
Q260=+20 ;CLEARANCE HEIGHT
Q301=0 ;MOVE TO CLEARANCE
Q305=12 ;NUMBER IN TABLE
Q331=+0 ;DATUM
Q332=+0 ;DATUM
Q303=+1 ;MEAS. VALUE
TRANSFER
Q381=1 ;PROBE IN TS AXIS
Q382=+85 ;1ST CO. FOR TS AXIS
Q383=+50 ;2ND CO. FOR TS AXIS
Q384=+0 ;3RD CO. FOR TS AXIS
Q333=+1 ;DATUM
Q423=4 ;NO. OF PROBE POINTS
Q365=1 ;TYPE OF TRAVERSE

Table of Contents