EasyManua.ls Logo

HEIDENHAIN TNC 320 - Cycle Parameters

HEIDENHAIN TNC 320
465 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Touch Probe Cycles: Automatic Workpiece Inspection
15.6 MEASURE HOLE OUTSIDE (Cycle 422, DIN/ISO: G422)
15
392
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
Cycle parameters
Q273 Center in 1st axis (nom. value)? (absolute):
Center of the stud in the reference axis of the
working plane. Input range -99999.9999 to
99999.9999
Q274 Center in 2nd axis (nom. value)? (absolute):
Center of the stud in the secondary axis of
the working plane. Input range -99999.9999 to
99999.9999
Q262 Nominal diameter?: Enter the diameter of the
stud. Input range 0 to 99999.9999
Q325 Starting angle? (absolute): Angle between
the reference axis of the working plane and the first
touch point. Input range -360.000 to 360.000
Q247 Intermediate stepping angle? (incremental):
Angle between two measuring points. The algebraic
sign of the stepping angle determines the direction
of rotation (negative = clockwise). If you wish to
probe a circular arc instead of a complete circle,
then program the stepping angle to be less than
90°. Input range -120.0000 to 120.0000
Q261 Measuring height in probe axis? (absolute):
Coordinate of the ball tip center (= touch point) in
the touch probe axis in which the measurement is
to be made. Input range -99999.9999 to 99999.9999
Q320 Set-up clearance? (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP in the touch probe table.
Input range 0 to 99999.9999
Q260 Clearance height? (absolute): coordinate in
the touch probe axis at which no collision between
tool and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999
Q301 Move to clearance height (0/1)?: Definition
of how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Q277 Maximum limit of size for stud?: Maximum
permissible diameter for the stud Input range 0 to
99999.9999
Q278 Minimum limit of size for stud?: Minimum
permissible diameter for the stud. Input range 0 to
99999.9999
NC blocks
5 TCH PROBE 422 MEAS. CIRCLE
OUTSIDE
Q273=+50 ;CENTER IN 1ST AXIS
Q274=+50 ;CENTER IN 2ND AXIS
Q262=75 ;NOMINAL DIAMETER
Q325=+90 ;STARTING ANGLE
Q247=+30 ;STEPPING ANGLE
Q261=-5 ;MEASURING HEIGHT
Q320=0 ;SET-UP CLEARANCE
Q260=+10 ;CLEARANCE HEIGHT
Q301=0 ;MOVE TO CLEARANCE
Q277=35.15;MAXIMUM LIMIT
Q278=34.9 ;MINIMUM LIMIT
Q279=0.05 ;TOLERANCE 1ST
CENTER
Q280=0.05 ;TOLERANCE 2ND
CENTER

Table of Contents

Other manuals for HEIDENHAIN TNC 320

Related product manuals