BASIC ROTATION compensation via rotary axis (Cycle 403,
DIN/ISO: G403)
13.5
13
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
317
Q301 Move to clearance height (0/1)?: Definition
of how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Q312 Axis for compensating movement?:
Assignment of the rotary axis in which the TNC is to
compensate the measured misalignment:
0: Automatic mode – the TNC uses the active
kinematics to determine the rotary axis to be
aligned. In Automatic mode the first rotary axis of
the table (as viewed from the workpiece) is used
as compensation axis. This is the recommended
setting.
4: Compensate misalignment with rotary axis A
5: Compensate misalignment with rotary axis B
6: Compensate misalignment with rotary axis C
Q337 Set to zero after alignment?: Define
whether the TNC should set the angle of the aligned
rotary axis to 0 in the preset table or in the datum
table after the alignment.
0: Do not set the angle of the rotary axis to 0 in the
table after alignment
1: Set the angle of the rotary axis to 0 in the table
after alignment
Q305 Number in table? Enter the number in the
preset table/datum table in which the TNC is to set
the rotary axis to zero. Only effective if Q337 is set
to 1. Input range 0 to 99999
Q303 Meas. value transfer (0,1)?: Specify if the
determined basic rotation is to be saved in the
datum table or in the preset table:
0: Write the measured basic rotation as datum shift
active datum table. The reference system is the
active workpiece coordinate system
1: Write the measured basic rotation into the
preset table. The reference system is the machine
coordinate system (REF system).
Q380 Ref. angle in ref. axis?: Angle with which
the TNC is to align the probed straight line. Only
effective if the rotary axis = Automatic mode or C
is selected (Q312 = 0 or 6). Input range -360.000 to
360.000
Q301=0 ;MOVE TO CLEARANCE
Q312=0 ;COMPENSATION AXIS
Q337=0 ;SET TO ZERO
Q305=1 ;NUMBER IN TABLE
Q303=+1 ;MEAS. VALUE
TRANSFER
Q380=+90 ;REFERENCE ANGLE