DATUM FROM OUTSIDE OF CIRCLE (Cycle 413, DIN/ISO: G413) 14.7
14
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
349
Q305 Number in table?: Enter the number in the
datum/preset table in which the TNC is to save
the coordinates of the stud center. If Q303=1: If
you enter Q305=0, the TNC automatically sets the
display so that the new datum is on the stud center.
If Q303=0: If you enter Q305=0, the TNC writes to
line 0 of the datum table. Input range 0 to 99999
Q331 New datum in reference axis? (absolute):
Coordinate in the reference axis at which the TNC
should set the stud center. Default setting = 0. Input
range -99999.9999 to 99999.9999
Q332 New datum in minor axis? (absolute):
Coordinate in the minor axis at which the TNC
should set the stud center. Default setting = 0. Input
range -99999.9999 to 99999.9999
Q303 Meas. value transfer (0,1)?: Specify whether
the determined reference point is to be saved in the
datum table or in the preset table:
–1: Do not use! Is entered by the TNC when old
programs are read in (see "Characteristics common
to all touch probe cycles for datum setting",
page 326)
0: Write the measured datum into the active datum
table. The reference system is the active workpiece
coordinate system
1: Write the measured datum into the preset table.
The reference system is the machine coordinate
system (REF system).
Q381 Probe in TS axis? (0/1): Specify whether the
TNC should also set the datum in the touch probe
axis:
0: Do not set the datum in the touch probe axis
1: Set the datum in the touch probe axis
Q382 Probe TS axis: Coord. 1st axis? (absolute):
Coordinate of the probe point in the reference axis
of the working plane at which point the datum is
to be set in the touch probe axis. Only effective if
Q381 = 1. Input range -99999.9999 to 99999.9999
Q383 Probe TS axis: Coord. 2nd axis? (absolute):
Coordinate of the probe point in the minor axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 =
1. Input range -99999.9999 to 99999.9999
Q303=+1 ;MEAS. VALUE
TRANSFER
Q381=1 ;PROBE IN TS AXIS
Q382=+85 ;1ST CO. FOR TS AXIS
Q383=+50 ;2ND CO. FOR TS AXIS
Q384=+0 ;3RD CO. FOR TS AXIS
Q333=+1 ;DATUM
Q423=4 ;NO. OF PROBE POINTS
Q365=1 ;TYPE OF TRAVERSE