DATUM IN ONE AXIS (Cycle 419, DIN/ISO: G419) 14.13
14
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
371
Q333 New datum in TS axis? (absolute): Coordinate
at which the TNC should set the datum. Default
setting = 0. Input range -99999.9999 to 99999.9999
Q303 Meas. value transfer (0,1)?: Specify whether
the determined reference point is to be saved in the
datum table or in the preset table:
–1: Do not use! Is entered by the TNC when old
programs are read in (see "Characteristics common
to all touch probe cycles for datum setting",
page 326)
0: Write the measured datum into the active datum
table. The reference system is the active workpiece
coordinate system
1: Write the measured datum into the preset table.
The reference system is the machine coordinate
system (REF system).