MEASURE INSIDE WIDTH (Cycle 425, DIN/ISO: G425) 15.9
15
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
403
Q330 Tool for monitoring?: Definition of
whether the TNC is to monitor the tool (see "Tool
monitoring", page 380). Input range 0 to 32767.9,
alternatively tool name with maximum of 16
characters
0: Monitoring inactive
>0: Number or name of the tool that the TNC used
for machining. You are able to apply a tool via soft
key directly from the tool table.
Q320 Set-up clearance? (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP (touch probe table), and
is only effective when the datum is probed in the
touch probe axis. Input range 0 to 99999.9999
Q301 Move to clearance height (0/1)?: Definition
of how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points