MEASURE COORDINATE (Cycle 427, DIN/ISO: G427) 15.11
15
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
409
Q288 Maximum limit of size?: Maximum
permissible measured value. Input range 0 to
99999.9999
Q289 Minimum limit of size?: Minimum
permissible measured value. Input range 0 to
99999.9999
Q309 PGM stop if tolerance exceeded?: Definition
of whether in the event of a violation of tolerance
limits the TNC is to interrupt program run and output
an error message:
0: Do not interrupt program run, do not output an
error message
1: Interrupt program run and output an error
message
Q330 Tool for monitoring?: Definition of
whether the TNC is to monitor the tool (see "Tool
monitoring", page 380). Input range 0 to 32767.9,
alternatively tool name with maximum of 16
characters
0: Monitoring inactive
>0: Number or name of the tool that the TNC used
for machining. You are able to apply a tool via soft
key directly from the tool table.
Parameters Q498 and Q531 have no effect in this
cycle. You do not need to make any entries. These
parameters have only been integrated for reasons of
compatibility. If, for example, you import a program
of the contouring control for turning and milling,
TNC 640, you will not receive an error message.
Q289=4.95 ;MINIMUM LIMIT
Q309=0 ;PGM STOP TOLERANCE
Q330=0 ;TOOL
Q498=0 ;REVERSE TOOL
Q531=0 ;ANGLE OF INCIDENCE?