EasyManuals Logo

HIKVISION DS-9616NI-I8 User Manual

HIKVISION DS-9616NI-I8
213 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
Network Video Recorder User Manual
99
Figure 8-5 Array List
8.2.3 Manually Rebuild an Array
Purpose
If no hot spare disks are configured, rebuild a degraded array manually.
Before You Start
At least one available physical disk must exist to rebuild an array.
Step 1 Go to Storage > RAID Setup > Array.
Figure 8-6 Array List
Step 2 Click of the degraded array.
Figure 8-7 Rebuild Array
Step 3 Select the available physical disk.
Step 4 Click OK.
Step 5 Click OK on the pop up message box “Do not unplug the physical disk when it is under rebuilding.”

Table of Contents

Other manuals for HIKVISION DS-9616NI-I8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-9616NI-I8 and is the answer not in the manual?

HIKVISION DS-9616NI-I8 Specifications

General IconGeneral
Sequence modeYes
Internal memory4096 MB
Number of users128 user(s)
Maximum resolution3840 x 2160 pixels
Alarm input channels16
Internal memory typeDDR4
Throughput data rate256 Mbit/s
Video input channels16 channels
Alarm output channels4
Supported resolutions3840 x 2160, 2560 x 1440, 1920 x 1080, 1600 x1200, 1280 x 1024, 1280 x 720, 1024 x 768
Video formats supportedH.264, H.264+, H.265, MPEG4
Analog signal format systemNTSC, PAL
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet LAN (RJ-45) ports2
USB 3.2 Gen 1 (3.1 Gen 1) Type-A ports quantity1
RAID levels0, 1, 5, 10
HDD capacity8000 GB
HDD interfaceSerial ATA
Maximum storage capacity- TB
Number of HDDs installed-
Number of HDDs supported8
Total installed storage capacity16000 GB
Product colorBlack
Rack capacity2U
Operating temperature (T-T)-10 - 55 °C
Operating relative humidity (H-H)10 - 90 %
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (max)200 W
Weight and Dimensions IconWeight and Dimensions
Depth470 mm
Width445 mm
Height90 mm

Related product manuals