Note
If you select Access Con
troller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
Baud Rate
The baud r
ate when the devices are communicang via the RS-485 protocol.
Output Type
If you select Access Controller as the peripheral type, you should set the parameter. The device
will output the card No. or the employee ID to the access controller.
Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
Note
Some device models do not support this funcon. Refer to the actual products when conguraon.
1. Click Conguraon → Access Con
trol → Wiegand Sengs .
Figure 8-14 Wiegand Page
2. Check Wiegand to enable the Wiegand funcon.
3. Set a transmission direcon.
Input
The device can connect a Wiegand card reader.
Output
The can connect an external access controller. And the two devices will transmit the card No.
via Wiegand 26 or 34.
DS-K1T981 Series Access Control Terminal User Manual
103