EasyManua.ls Logo

HIKVISION DS-K1T981 Series

HIKVISION DS-K1T981 Series
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Set Wiegand Parameters
You can set the access control device's Wiegand channel and the communicaon mode. Aer
seng the Wiegand parameters, the device can connect to Wiegand card reader via Wiegand
communicaon.
Before You Start
Add access control device to the client, and make sure the device supports Wiegand.
Steps
1. Enter the Access Control module.
2. On the navigaon bar on the le, enter Advanced Funcon → More Parameters .
3. Select an access control device in the device list and click Wiegand to enter the Wiegand
Sengs page.
4. Set the switch to on to enable the Wiegand funcon for the device.
5. Select the Wiegand channel No. and the communicaon mode from the drop-down list.
Note
If you set Communicaon Direcon as Sending, y
ou are required to set the Wiegand Mode as
Wiegand 26 or Wiegand 34.
6. Click Sa
ve.
The congured parameters will be applied to the device automacally.
Aer changing the communicaon direcon, the device will reboot automacally.
Enable M1 Card Encrypon
M1 card encrypon can improve the security level of authencaon.
Steps
Note
The
funcon should be supported by the access control device and the card reader.
1. En
ter the Access Control module.
2. On the navigaon bar on the le, enter Advanced Funcon → More Parameters .
3. Select an access control device in the device list and click M1 Card Encrypon to enter the M1
Card Encrypon page.
4. Se
t the switch to on to enable the M1 card encrypon funcon.
5. Set the sector ID.
The sector ID ranges from 1 to 100.
6. Click Save to save the sengs.
DS-K1T981 Series Access Control Terminal User Manual
135

Table of Contents

Related product manuals