Page 8 199253
(6) -
EN
-
Accella™ Therapy Mattress Instructions for Use
Therapeutic Mattress
Characteristics Description
Model
P006783A-
P006788A-
P006789A
P006790A-
P006791A-
P006792A
P006793A-
P006794A
Dimension (inflated) 203x92x21.5 cm / 80x35.5x8.5’’
215x96x21.5 cm
/ 84.6x37.8x8.5’
Weight ~ 17.5 kg / ~ 37.5 lb
Voltage 220-240V 120V 220-240V
Frequency 50 Hz 60 Hz 50 Hz
Apparent power
ALP & CLP modes
Initial inflation
32 VA
146 VA
32 VA
146 VA
32 VA
146 VA
Maximum energy consumption 13 Wh 13 Wh 13 Wh
Operation of the device Continuous
Upper cover (applied part of the
device)
Polyurethane coating on Polyamide material, low-
friction, stretchable in both directions, breathing,
bacteriostatic; fungistatic and antimicrobial; can be
wiped and washed.
Volume of the device: in ALP or CLP
regulation mode / in MCM™ mode
only (ISO 3744)
<55dB(A) / <30dB(A)
Alarm: Sound pressure (ISO 3744) 44.6 dB(A)
Maximum compressor pressure
0 - 24.5 kPa
Maximum compressor flow rate
27.4 l/mn 30.1 l/mn 27.4 l/mn
Electric shock protection Class II
Class according to IEC 60601-1
Type BF applied parts protected against defibrillation
shocks (labeled 1 and 8 page 11)
Protection against inflammable
anesthetic mixtures
Not for use with flammable anesthetics.
Safe working load including the total weight of the
patient, accessories (if they are supported by the
support system of the medical bed) and the load
supported by these accessories (excluding the weight
of the patient).
Safe Working Load is the technical limit of patient
weight that can be applied after which a damage may
occur on the mattress.
Maximum pressure of the safety
valve
104 mBar
Degree of protection provided by the
cover (CEI 60529)
IP24: protection against splashes of water.
Battery:
Minimum battery life
Time to fully charge
2 hours
24 hours
Battery life with CPR/patient exit
alarm/low pressure alarm
2 hours
Patient support battery life
8 hours
250250

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hillrom Accella P006783A and is the answer not in the manual?

Hillrom Accella P006783A Specifications

General IconGeneral
BrandHillrom
ModelAccella P006783A
CategoryMedical Equipment
LanguageEnglish

Related product manuals