Using the Memory Function
If the memory No. for which the data have already been saved is
selected, [
] appears.
When MEM is pressed, the data are overwritten.
When the value is saved with memory No. “400” displayed, a buzzer
sounds and “FULL” appears in the display, and then “001” reappears.
When [
] (data reading) is displayed, it is not possible to save the
value.
The current value, maximum value (MAX), minimum value (MIN),
instantaneous maximum value (Peak max), and instantaneous minimum
value (Peak min) cannot be saved simultaneously. Only the displayed
numeric value can be saved.
The continuity check data and the diode test data cannot be saved.
When both hands cannot be used during measurement
Enable the auto hold function. After the measured value is retained
automatically, press MEM to save the data.
Items to be saved per data
Function
Measurement range
Measured value in the main
display
Measured value in the sub
display
Whether or not the REL function
is executed
Filter ON/OFF
HIOKI DT4281A981-08