1.3.6.1.4.1.31496.10.40.3.0
Getting the current config description:
snmpget -v 3 -u admin -n "" -l authNoPriv -a MD5 -x DES -A admin01admin01 192.168.1.1
1.3.6.1.4.1.31496.10.40.4.0
Getting the current config hash:
snmpget -v 3 -u admin -n "" -l authNoPriv -a MD5 -x DES -A admin01admin01 192.168.1.1
1.3.6.1.4.1.31496.10.40.5.0
Restarting the device:
snmpset -v 3 -u admin -n "" -l authNoPriv -a MD5 -x DES -A admin01admin01 192.168.1.1
1.3.6.1.4.1.31496.10.40.10.0 i 1
Running a configuration update:
snmpset -v 3 -u admin -n "" -l authNoPriv -a MD5 -x DES -A admin01admin01 192.168.1.1
1.3.6.1.4.1.31496.10.40.11.0 s "http://server/directory"
You can use TFTP, HTTP, HTTPS and FTP URLs (specifying a username/password or a port is not yet
supported).
Please note that config updates expect a zip-file named <serial-number>.zip in the specified direc-
tory.
Getting the configuration update status:
snmpget -v 3 -u admin -n "" -l authNoPriv -a MD5 -x DES -A admin01admin01 192.168.1.1
1.3.6.1.4.1.31496.10.40.12.0
The return value can be one of: succeeded (1), failed (2), inprogress (3), notstarted (4).
Running a software update:
snmpset -v 3 -u admin -n "" -l authNoPriv -a MD5 -x DES -A admin01admin01 192.168.1.1
1.3.6.1.4.1.31496.10.40.13.0 s "http://server/directory"
Getting the software update status:
snmpget -v 3 -u admin -n "" -l authNoPriv -a MD5 -x DES -A admin01admin01 192.168.1.1
1.3.6.1.4.1.31496.10.40.14.0
The return value can be one of: succeeded (1), failed (2), inprogress (3), notstarted (4).
Setting the update operation:
snmpset -v 3 -u admin -n "" -l authNoPriv -a MD5 -x DES -A admin01admin01 192.168.1.1
1.3.6.1.4.1.31496.10.40.15.0 i 1
By default, the update operation is set to update (0) which results in an immediate update of software
or configuration once triggered. One may also set the operation to store (1) which will only store the
software or configuration package. It can be later activated using the following switch operators.