esteblish a mobile data connection automatically. This feature is highly dependent on the SIM card
features and the available networks.
This Option is only availble if the router is equipped with a cellular module.
6.1.3. Recovery
Following actions might be taken in case the router has been misconfigured and cannot be reached
anymore:
1. Factory Reset: You can initiate a reset back to factory settings via the Web Manager, by running
the command factory-reset or by pressing the reset button. The latter would require a slim
needle or paper clip which must be inserted into the hole to the right of the USB port. The button
must be hold pressed for up to 5 seconds until all LEDs flash up.
2. Serial Console Login: It is also possible to log into the system via the serial port. This requires
a terminal emulator (such as PuTTY or HyperTerminal) and an RS232 connection (115200 8N1)
attached to the serial port of your local computer. You will also see the kernel messages at
bootup there.
3. Recovery Image: In severe cases we can provide a recovery image on demand which can be
loaded into RAM via TFTP and executed. It offers a minimal system image for running a software
update or doing other modifications. You will be provided with two files, recovery-image and
recovery-dtb, which must be placed in the root directory of a TFTP server (connected via LAN1
and address 192.168.1.254). The recovery image can be launched from the bootloader using a
serial connection. You will have to stop the boot process by pressing s and enter the bootloader.
You can then issue run recovery to load the image and start the system which can be accessed
via HTTP/SSH/Telnet and its IP address 192.168.1.1 afterwards. This procedure can be also
initiated by holding the factory reset button longer than 15 seconds.