8.
ERROR
MESSAGE
8.1
Error
Message
of
Digital
Adjustment
ERROR
MESSAGE
COUNTERMEASURE
ERROR
OCCURRED.
IRIS
TROUBLE
-
Check
whether
or
not
power
ts
supplied.
PRESS
ANY
KEY
-
Check
the
values
of
the
iris
drive
circuit.
-
Defective
soldering,
damage
to
pattern,
etc.
in
the
above
circuit.
-
Check
the
iris
block
and
replace
it if
necessary.
-
Check
the
values
in
the
hall
amp
circuit.
ERROR
OCCURRED
ON
dax
ADJUSTMENT
PRESS
ANY
KEY
-
Defective
soldering,
damage
to
pattern,
etc.
in
the
above
circuit.
D
RANGE
OVER.
ERROR
ON
dax
ADJUSTMENT
-
Check
the
values
in
the
hall
amp
circuit.
PRESS
ANY
KEY.
-
Defective
soldering,
damage
to
pattern,
etc.
in
theabove
circuit.
ERROR
OCCURRED
ON
da0
and
da1
ADJUSTMENT
-
Check
the
values
in
the
hall
amp
circuit
and
its
peripheral
circuits.
-
Defective
soldering
PRESS
ANY
KEY
damage
to
pattern,
etc.
in
the
above
circuits.
FILE
NOT
FOUND
!!!!
-
The
adjustment
program
(file)
cannot
be
found.
PRESS
ANY
KEY
-
Check
the
adjustment
floppy
disk
and
replace
it
if
necessary.
FILE
OPEN
ERROR
!!!!
-
The
adjustment
program
(file)
does
not
start.
PRESS
ANY
KEY
-
Check
the
adjustment
floppy
disk
and
replace
it
if
necessary.
-
Check
the
values
of
the
iris
drive
circuit.
-
Defective
soldering,
damage
to
pattern,
etc.
in
the
above
circuit.
-
Supply
power
again
and
re-adjust.
PRESS
ANY
KEY
ERROR
OCCURRED
ON
FDET
ADJUSTMENT
-
Check
the
values
in
the
hall
amp
circuit.
PRESS
ANY
KEY
-
Defective
soldering,
damage
to
pattern,
etc.
in
the
above
circuit.
PRESS
ANY
KEY
PRESS
ANY
KEY
-
Move
the
camera
further
away
from
the
light
box.
TOO
DARK
-
The
subject
is
too
dark.
PRESS
ANY
KEY
-
Check
the
light
box.
-
Move
the
camera
closer
to
the
light
box.
-
Supply
power
again
and
re-adjust.
-
The
subject
is
too
dark.
-
Check
the
light
box.
-
Move
the
camera
closer
to
the
light
box.
-
Check
the
values
in
the
hall
amp
circuit.
-
Defective
soldering,
damage
to
pattern,
etc.
in
the
above
circuit.
PRESS
ANY
KEY
:
Move
the
camera
further
away
from
the
light
box.
CAN'T
ADJUST
WHITE
BALANCE
-
The
subject
is
too
bright
or
too
dark.
PLEASE
RETRY
-
Check
the
light
box.
PRESS
ANY
KEY
-
Move
the
camera
closer
to
or
away
from
the
light
box.
-
Supply
power
again
and
re-adjust.
D
RANGE
OVER
ERROR
ON
HALL
AMP
IRIS
CANNOT
OPEN
ANY
MORE
PRESS
ANY
KEY
E3
-
17

Table of Contents