Specifications 
Environmental specifications 
Specification  Value 
Temperature range 
1 
— 
Operating  10°C to 35°C (50°F to 95°F) 
Nonoperating  -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)  — 
Operating 
Minimum to be the higher (more moisture) of -12°C 
(10.4°F) dew point or 8% relative humidity 
Maximum to be 24°C (75.2°F) dew point or 90% 
relative humidity 
Nonoperating 
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature 
1 
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft) to 3048 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper 
limit and rate of change might be limited by the type and number of options installed. 
For certain approved hardware configurations, the supported system inlet temperature range is extended: 
• 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C
per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
• 40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per
every 410 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
For information about approved hardware configurations, contact customer support. 
Mechanical specifications 
Specification  Value 
Height  8.75 cm (3.44 in) 
Depth, SFF  72.70 cm (28.62 in) 
Depth, LFF  73.25 cm (28.84 in) 
Width  44.80 cm (17.64 in) 
Weight, SFF minimum  16.00 kg (35.27 lbs) 
Weight, SFF maximum  37.00 kg (81.57 lbs) 
Table Continued