9. Install the server in the rack.
10. Connect each power cord to the server.
11. Connect each power cord to the power source.
12. Power up the server.
The installation is complete. 
Management 
Installing the Systems Insight Display 
Prerequisites 
Before you perform this procedure, make sure that you have the following items available: 
• The components included with the hardware option kit
• T-10 Torx screwdriver
About this task 
The Systems Insight Display is only supported on SFF models. 
Procedure 
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
• Extend the server from the rack.
• Remove the server from the rack.
4. Remove the access panel.
5. Do one of the following:
• Remove the air baffle.
• If installed, remove the midplane drive cage.
6. Remove the fan cage.
7. Using a T-10 driver, remove the power switch module blank. Retain the T-10 screw.