Chapter 9 Inverter Functions
9-14-10
Origin setting using the current position clear function
Assigning "Clearance of position deviation [PCLR] (47)" to the input terminal and turning on that
terminal clears "Current position monitor [d030]" to zero.
Moving to the position that will be the origin beforehand and turning on [PCLR] determines the
origin.
[PCLR] is enabled when "Pulse input, target function selection [P003]" is set to "Speed feedback
(01)" regardless of the setting of "Simple positioning selection [P012]".
Code
Item
Description
Data
[C001]
to
[C007]
Input terminal
function
Clearance of position deviation [PCLR]:
When "Pulse input, target function selection [P003]" is
"Speed feedback (01)", turning this signal on clears
"Current position monitor [d030]" to zero.
47
Origin setting using the current position preset function
The current position preset function specifies the current position to the position set in "Pre-set
position data [P083]". This is used when there is an offset between the origin position ([ORL]
signal input position) and the actual origin when the returning function is used.
Assigning "Position data presetting [PSET] (91)" to the input terminal and turning on that
terminal allows "Current position monitor [d030]" to be "Pre-set position data [P083]".
When using the current position preset function, set "Position control mode selection [P075]" to
"Limit (00)". When "No Limit (01)" is selected, it is not enabled.
[PSET] is enabled when "Pulse input, target function selection [P003]" is set to "Speed feedback
(01)" regardless of the setting of "Simple positioning selection [P012]".
Code
Item
Description
Data
[P075]
Position
control mode
selection
When using the current position preset function, select
"Limit (00)".
00
[P083]
Pre-set
position data
Sets the preset value of the position data.
(The setting range is limited to "Position control range
(reverse) [P073]" to "Position control range (forward)
[P072]".)
[P073]
to
[P072]
[C001]
to
[C007]
Input terminal
function
Position data presetting [PSET]:
When "Pulse input, target function selection [P003]" is
"Speed feedback (01)", if this signal is turned on,
"Current position monitor [d030]" becomes the value of
" Pre-set position data [P083]".