3.2.3 Connecting Remote Operator
How to operate the inverter by putting operator keypad on the front of the control panel on
which the inverter is installed?
Connecting the optional remote operator (OPE-SR, OPE-SBK, OPE-SRmini, WOP) enables
operation from outside the panel.
It is recommended to use the connector cable option ICS-1 (1 m) or ICS-3 (3 m) to connect the
inverter main unit and the remote operator.
When preparing the connector cable by yourself, use the following cables or cables with
equivalent specifications.
■ TSUKO Cat5e cable with connectors at both ends (twisted wire)
Model: TSUNET-MC350E-MP 8C B 8-8
■ Hitachi Metals, Ltd. Straight wire with connectors at both ends
Model: NETSTAR-C5E PC 24AWGX4P
Use a connector cable within 3 m. If the cable is more than 3 m, it may cause malfunctioning.
Do not connect or disconnect the remote operator while the inverter is energized.