Chapter 11 RS485 Communication
11-2-5
If the command cannot be executed successfully, an exceptional response is returned. For
details, refer to "11.2.9 Exceptional Responses".
The writing to the coil numbers 0001h to 000Fh can also be substituted in the holding register
to the register number 1F01h. As an example, the bit-structure of the holding register 1F01h is
shown below. For details, refer to "18.1.1 List of Modbus Coil Numbers".
bit
Symbol
Item
bit
Symbol
Item
15
-
-
7
IN1
Input terminal 1 function
(0:OFF/1:ON)
14
-
-
6
-
-
13
IN7
Input terminal 7 function
(0:OFF/1:ON)
5
-
-
12
IN6
Input terminal 6 function
(0:OFF/1:ON)
4
RS
Reset
11
IN5
Input terminal 5 function
(0:OFF/1:ON)
3
EXT
External fault
10
IN4
Input terminal 4 function
(0:OFF/1:ON)
2
-
Rotation direction (0:
Forward/1: Reverse)
9
IN3
Input terminal 3 function
(0:OFF/1:ON)
1
-
RUN command (0: Stop/1: Run)
8
IN2
Input terminal 2 function
(0:OFF/1:ON)
0
-
-
!